Monitoring

 

 

ê This function requires the licensing of the Monitoring module.

 

 

 

i An overview of integrated monitoring is to be found in the web interface under Configuration - Monitoring.

 

 

Configure checks which check your system at a Time interval of 5 minutes and reliably report failures:

 

 

Checks

 

Options for all checks

 

Option Description
Name Give your check a name.
Notification group

Select a group of contacts which are to receive notifications.

 

If the monitoring system of your SMS Gateway notices a failure, a group of contacts will be alerted by text message or by "Automatic".

 

The monitoring group is intended for this purpose as standard. After the failure has been cleared the SMS Gateway will send a recovery message.

 

 

ê If you have licensed the Recipient groups module, you have the option to notify further groups.

 

Shipping option

Select the shipping option of the notifications.

 

The monitoring system provides two different shipping options: "Only SMS" and Automatic".

 

Automatic trys to deliver the notification via Telegram, if it fails the notification will be delivered by text message.

 

 

ê Licensing for the Telegram module is required. This licensing is free of charge for support customers. Please contact sales@brevis.one.

 

 

 

 

Available Checks

 

Name of the check

Arguments

CheckHTTPAuth

 

To monitor websites with HTTP authentication

Website

Enter the website to be monitored, e.g.: http://www.brevis.one/secure

 

User name

Enter the user name which is to be used for logging in

 

Password

Enter the password for the user

CheckHTTP

 

To monitor websites

Website

Enter the website to be monitored, e.g.: http://www.brevis.one

CheckPort

 

To monitor the reachability of services

Host

Enter the host to be monitored: 192.168.1.254 or www.brevis.one

 

Port

Enter the port which is to be monitored, e.g.: 80

 

Timeout

Enter the timeout for the reachability of the port

Ping

 

To monitor availabilities

Host

Specify the host to be monitored, e.g.: 192.168.1.254 or www.brevis.one

 

Number of pings

Enter the number of ICMP Echo Requests per check interval to be set

 

Timeout

Enter the timeout for the individual ICMP Echo Requests

 

 

Re-notification time

 

The re-notification time is the time interval in minutes after which a new alert is sent if a failure lasts longer.

 

 

Maximum amount checks

 

The SMS Gateway Monitoring allows to have up to 200 individual checks.

 

 

Example


 

 

Click the Export button to save your settings, e.g. before a Firmware update.

 

 

 

 